Constant Current Compact Non dimmable

- Installation in emergency lighting systems according to IEC 61347-2-13, appendix J
- Suitable for indoor SELV installations
- Suitable for luminaires of protection classes I and II
OPTOTRONIC FIT LT2 LP
- Supply voltage: 220 240 V
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Line voltage: 198 264 V
- According to EN 61347-1, 61347-2-13, 62384
- RI suppression: to EN 55015
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
- Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
Kevesebb Bővebben

- Suitable for indoor SELV installations
- Suitable for luminaires of protection classes I and II
OPTOTRONIC FIT LT2 S
- Supply voltage: 220 240 V
- Line frequency: 50 Hz | 60 Hz
- Line voltage: 198 264 V
- According to EN 61347-1, 61347-2-13, 62384
- RI suppression: to EN 55015
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
- Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
- Cable clamp kit for independent mounting
Kevesebb Bővebben

- Suitable for luminaires of protection classes I and II
OPTOTRONIC FIT CS G2
- Supply voltage: 220 240 V
- Line frequency: 50 Hz | 60 Hz
- Line voltage: 198 264 V
- According to EN 61347-1, 61347-2-13, 62384
- RI suppression: to EN 55015
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
- Cable clamp kit for independent mounting
Kevesebb Bővebben

- Suitable for luminaires of protection classes I and II

- Suitable for luminaires of protection classes I and II
- Suitable for indoor SELV installations
OPTOTRONIC FIT CS MINI
- Supply voltage: 220 240 V
- Line frequency: 50 Hz | 60 Hz
- Line voltage: 198 264 V
- According to EN 61347-1, 61347-2-13, 62384
Kevesebb Bővebben

OPTOTRONIC FIT CS Track
- Supply voltage: 220 240 V
- Line frequency: 50 Hz | 60 Hz
- Line voltage: 198 264 V
- Lifetime: up to 50,000 h (temperature at Tc = 75 °C, max. 10 % failure rate)
Kevesebb Bővebben

- Suitable for indoor SELV installations
- Suitable for luminaires of protection classes I and II
OPTOTRONIC FIT CS G1
- Supply voltage: 220 240 V
- Line frequency: 0 Hz | 50 Hz | 60 Hz
- Line voltage: 198 264 V
- Safety according to EN 61347-1, 61347-2-3, 61347-2-13, 62384
- RI suppression: to EN 55015/CISPR 15
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
- Lifetime: up to 100,000 h (temperature at Tc = 65 °C, max. 10 % failure rate)
- LED protection by Hot Plug
Kevesebb Bővebben

- Spot light and down light
- Offices
- Shops
OPTOTRONIC FIT NFC
- Output current range 150-1050 mA
- NFC Interface
- Low LF-ripple < 5%
Kevesebb Bővebben
.jpg)
- Suitable for use in luminaires with flexible current setting (Tri-Tap)
- Suitable for indoor SELV installations
- Suitable for luminaires of protection classes I and II
OPTOTRONIC ECO
- Supply voltage: 220 240 V
- Line frequency: 50 Hz | 60 Hz
- Line voltage: 198 264 V
- According to EN 61347-1, 61347-2-13, 62384
- RI suppression: to EN 55015/CISPR 15
- Line harmonics according to EN 61000-3-2
- Immunity according to EN 61547
Kevesebb Bővebben

- Suitable for luminaires of protection classes I and II
- Suitable for indoor SELV installations